Fuse Box & Consumer Unit Upgrades

Safer Consumer Unit Upgrades Across London for Homes, Landlords & Businesses

Replace an outdated fuse box with a modern consumer unit that gives your property stronger electrical protection. Benjamin Services checks the existing installation, installs suitable RCD or RCBO protection, tests the completed work and provides the appropriate certification with a clear handover when the upgrade is finished.

Book an Upgrade
Why an Upgrade Matters FAQs
⚡ Consumer Unit Replacement & Fuse Box Upgrades Across London

A Safer, Better-Organised Consumer Unit for Your Property

An old fuse box can make everyday faults harder to manage and may leave circuits without the level of protection expected from a modern installation. Benjamin Services replaces outdated boards with carefully selected consumer units, using suitable RCBO, RCD and SPD protection where required. We inspect the existing installation, complete the changeover, test every reconnected circuit and provide clear certification when the work is finished.

Modern metal consumer unit options Individual circuit protection with RCBOs Testing, certification and clear circuit labelling
Your upgrade at a glance
Survey Board size, circuit count, earthing and existing condition
Upgrade Consumer unit selected around the property and future demand
Handover Testing, EIC, labels and Part P notification where applicable

A consumer unit replacement is not the same as a full rewire. Any faults found in the existing circuits are explained separately before additional remedial work begins.

01 The Upgrade

What Is a Consumer Unit Upgrade?

It is the replacement of an older fuse box or distribution board with a modern consumer unit designed to control, isolate and protect the property’s electrical circuits more effectively.

  • Old equipment is safely isolated and removed
  • Existing circuits are transferred into the new board
  • Protective devices are selected to suit the installation
  • Every connected circuit is inspected and tested
02 Common Reasons

When Is an Upgrade Worth Considering?

  • An older board still uses rewireable fuses
  • There is limited or no RCD protection
  • The enclosure is damaged, overcrowded or poorly labelled
  • Circuits trip repeatedly and the cause needs investigation
  • Renovation, rewiring, EV charging or new circuits are planned
03 What You Receive

A Complete, Documented Changeover

  • A correctly sized consumer unit for the agreed work
  • Clear circuit identification and updated schedules
  • Inspection and test results for reconnected circuits
  • An Electrical Installation Certificate
  • Building Regulations notification where the work is notifiable
Survey and pre-installation checks

What We Review Before Replacing the Consumer Unit

A reliable quote needs more than a photograph of the old board. We look at the circuits, supply arrangements, available space and the condition of the installation so the proposed unit suits the property.

01

Number of Circuits

We count existing circuits and allow sensible spare capacity for likely future work.

02

Earthing & Bonding

Main earthing, protective conductors and bonding arrangements are checked before changeover.

03

Existing Circuit Condition

Initial checks help identify faults that may affect reconnection or cause a new RCBO to trip.

04

Supply & Meter Area

Service equipment, meter tails, isolators and available working space are reviewed.

05

Board Location & Access

Restricted cupboards, high-level boards and difficult cable entries can affect labour and materials.

06

Future Electrical Demand

Planned extensions, kitchens, heat pumps, EV chargers or other new loads are considered.

Protection chosen around the installation

Which Consumer Unit Setup Is Right for the Property?

There is no single board specification for every building. The right arrangement depends on the circuits, equipment in use, supply type, risk profile and any future additions. We explain the options in plain English before recommending a final specification.

RCBO

Individual Circuit Protection

Each circuit has its own combined overcurrent and residual-current protection, helping reduce the number of circuits affected by one fault.

SPD

Surge Protection

A Surge Protective Device helps protect the electrical installation and connected equipment from transient overvoltage events.

AFDD

Additional Arc-Fault Protection

AFDD protection may be required or recommended for selected circuits and property types. Suitability is reviewed as part of the design.

Device selection must match the installation and the equipment likely to be used. We do not recommend a board simply because it is the cheapest option.

Clear service boundaries

What Is Not Automatically Included in a Board Change?

The quotation covers the consumer unit work listed in your proposal. Repairs to unrelated faults, alterations to the supply equipment and extra circuits remain separate unless they are clearly included.

  • A full property rewire or replacement of ageing circuit cables
  • Remedial work for faults discovered during testing
  • Meter, service head or network equipment owned by the supplier or DNO
  • New circuits for cookers, showers, extensions or EV chargers
  • Builder’s work, decoration or cupboard alterations unless agreed
  • Asbestos investigation or specialist access equipment
What to expect

A Careful Four-Step Consumer Unit Changeover

Power is isolated during the work. We keep the process organised, protect the working area and explain any issue before it changes the agreed scope.

  1. 01

    Survey & Final Specification

    We confirm circuits, board type, protective devices, access and the agreed price.

  2. 02

    Safe Isolation & Removal

    The supply is isolated, the old board is disconnected and existing conductors are identified.

  3. 03

    Install & Reconnect

    The new consumer unit is fitted, circuits are terminated and protective devices are configured.

  4. 04

    Test, Label & Certify

    Circuits are tested, schedules are completed and the finished work is handed over clearly.

Before the appointment

How to Prepare for the Upgrade

A little preparation keeps the shutdown shorter and gives us safe access to the board.

  • Clear stored items from around the consumer unit
  • Save work and safely shut down computers and sensitive equipment
  • Plan for a temporary power interruption during the changeover
  • Tell us about alarms, medical equipment, servers or essential supplies
  • Provide any previous EICR, certificates or circuit information
  • Let tenants, staff or building managers know the planned shutdown time
Evidence behind the finished work

Testing, Certification and Building Regulations Records

Replacing the board is only part of the job. Existing circuits connected to the new consumer unit must be inspected and tested. The results show how the installation performed on the day and help document the completed changeover.

EIC

Electrical Installation Certificate

Records the new work, responsible parties, inspection and test results.

TEST

Circuit Test Schedule

Documents the measured results for circuits connected to the replacement board.

P

Part P Notification

Domestic consumer unit replacement is notified where required under Building Regulations.

MAP

Labels & Circuit Schedule

The board is labelled so circuits and protective devices are easier to identify.

When existing wiring needs attention

What Happens if Testing Finds an Existing Fault?

A modern RCBO board can reveal faults that an older fuse box did not disconnect for. We identify the affected circuit, explain the risk and agree the safest next step before carrying out work outside the quotation.

01

Identify the Circuit

Testing narrows the issue down to the affected circuit or equipment.

SAFE

Make the Situation Safe

A dangerous or unreliable circuit may need to remain isolated.

INFO

Explain the Finding

We tell you what was found and why it prevents normal reconnection.

£

Provide a Separate Price

Additional fault finding or remedial work is quoted clearly before it begins.

FIX

Repair Where Agreed

Approved remedial work is completed with disruption kept as low as practical.

Retest and Record

The circuit is retested and the final outcome is added to the documentation.

Transparent London guide pricing

How Consumer Unit Upgrade Prices Are Calculated

The cost is mainly shaped by the number of circuits, the consumer unit specification, access, earthing arrangements and the condition of the wiring being reconnected. These ranges are planning guides rather than automatic fixed prices.

Small Flat
Typical guide range£550–£700
Usually 4–6 existing circuits
  • Compact metal consumer unit
  • Standard RCBO and SPD specification
  • Installation, testing and certification
Request a Small-Board Quote
Larger Property
Typical guide range£950–£1,400+
Usually 11+ circuits or complex access
  • Larger board with spare capacity
  • More testing and circuit identification
  • Price adjusted for board and site complexity
Request a Larger-Board Quote
Specialist Design
Surveyed and specifiedTailored Quote
HMO, commercial, AFDD or non-standard work
  • Special protection or distribution requirements
  • Three-phase or multiple-board arrangements
  • Out-of-hours and managed-site planning
Discuss a Specialist Upgrade
Landlords, HMOs, Shops and Managed Portfolios Multi-property and commercial quotations are planned around board type, operating hours, shutdown arrangements, access, circuit records and whether several visits can be grouped together. Request a Tailored Quote
Normally included Agreed board, protective devices, installation, standard testing and certification.
Main price factors Circuit count, board specification, access, earthing and existing wiring condition.
Quoted separately Fault repairs, new circuits, supplier equipment, builders’ work and specialist access.
VAT & travel Benjamin Services is not currently VAT registered. Parking or exceptional travel costs are confirmed separately.

Guide prices assume a domestic single-phase installation with reasonable access and no major faults requiring repair. Your written quotation is confirmed after reviewing the postcode, photographs, circuit count, existing board and any pre-installation test information.

Consumer Unit Upgrades across London

Clear Specification. Careful Changeover. Proper Certification.

Send us the postcode, a clear photo of the existing fuse box, the property type and any planned electrical work. We will use those details to recommend the right survey or quotation route.

Why Consumer Unit Upgrades Matter

Why Replacing an Outdated Fuse Box Can Be a Valuable Upgrade

A modern consumer unit gives the property’s electrical circuits clearer, more responsive protection. It can improve fault isolation, add suitable RCD or RCBO protection and provide a better foundation for future electrical work.

Do not ignore warning signs: repeated tripping, buzzing or crackling, a burning smell, scorch marks, unusual heat or damage around the fuse box should be checked promptly. Avoid repeatedly resetting a device that will not remain on.

Electric shock and fault protection Stronger Protection for People and Individual Circuits

Older fuse boxes may offer limited residual-current protection or rely on arrangements that affect several circuits when one fault occurs. A carefully specified modern board can provide more focused protection.

  • RCD and RCBO protection can disconnect the supply quickly when certain fault currents are detected, helping reduce the risk of electric shock.
  • Individual RCBO protection can limit a fault to the affected circuit rather than disconnecting a larger group of circuits unnecessarily.
  • Pre-installation checks and final testing help confirm that the existing circuits can be safely connected to the new consumer unit.
Heat, damage and fire risk Replacing Ageing or Damaged Distribution Equipment

Age, loose connections, heat damage, poor alterations or an overcrowded board can make an old fuse box difficult to maintain safely. Replacement gives the installation a clean, properly organised point of distribution.

  • Heat-damaged fuse carriers, terminals or enclosures can indicate deterioration that needs investigation rather than another temporary repair.
  • A correctly installed metal consumer unit provides a robust enclosure for the protective devices and circuit connections.
  • Clear termination, labelling and testing help identify poor connections and confirm that the completed changeover performs as intended.
Control, isolation and future planning A Better-Organised Board for Today and Future Electrical Work

A consumer unit should suit the present installation while allowing sensible room for future demand. The board specification is chosen around the circuits, property type and any planned electrical improvements.

  • Clear circuit schedules and labels make it easier to identify and isolate lighting, sockets, cooking, heating and other supplies.
  • Surge protection can be included where specified to help protect the installation and connected equipment from transient overvoltage events.
  • Sensible spare capacity can support planned work such as extensions, kitchen upgrades, heat pumps, EV charging or additional circuits.
Testing, certification and records A Documented Changeover, Not Just a New Box on the Wall

Replacing a consumer unit involves inspecting and testing the circuits being reconnected. The completed work should leave the property owner with clear test information and the appropriate installation records.

  • An Electrical Installation Certificate records the new work, the inspection and the test results associated with the completed installation.
  • Part P notification is arranged where applicable for notifiable consumer unit replacement work in a dwelling in England.
  • Updated circuit schedules and labels give homeowners, landlords and future electricians a clearer record of the finished arrangement.

Consumer unit replacement and electrical safety information is based on guidance from GOV.UK Approved Document P , The Institution of Engineering and Technology and Electrical Safety First consumer-unit guidance .

Professional Consumer Unit Replacement

Safer Consumer Unit Upgrades Across London

Benjamin Services replaces outdated fuse boxes with carefully specified consumer units for homes, landlords, managing agents and businesses across London. We check the existing installation, install suitable circuit protection, test every reconnected circuit and provide clear certification when the upgrade is complete.

Pre-Upgrade Survey & Checks

We review the existing board, circuit count, earthing, bonding, supply arrangements and visible condition.

RCBO, RCD & SPD Protection

Protective devices are selected around the circuits, property type, equipment and agreed specification.

Safe Changeover & Labelling

The old board is removed safely, circuits are reconnected carefully and the new consumer unit is clearly labelled.

Testing, EIC & Part P Records

Reconnected circuits are tested and the appropriate Electrical Installation Certificate and notification are provided.

Benjamin Services Consumer Unit Guidance

Consumer Unit Upgrade Questions, Answered Clearly

Clear answers about old fuse boxes, RCBO and RCD protection, testing, power interruptions, Part P notification, certification and Consumer Unit Upgrade prices across London.

A new consumer unit must be specified around the existing installation

Circuit condition, earthing, supply arrangements, protective-device selection, access and future demand should be reviewed before the final board is chosen.

01 What is a consumer unit and what does it do?

A consumer unit, sometimes called a fuse box or distribution board, is the central point that controls and protects the electrical circuits in a property. It contains the main switch and protective devices for circuits such as lighting, sockets, cooking and heating. A modern consumer unit can provide clearer isolation, better circuit identification and protection selected around the installation.

02 When should I consider replacing an old fuse box?

An upgrade may be worth considering when the existing board still uses rewireable fuses, has limited RCD protection, is damaged, overcrowded, poorly labelled or unsuitable for planned electrical work. Repeated tripping, heat, buzzing, scorch marks or a burning smell also need prompt investigation. Age alone does not automatically mean replacement is required; condition, protection and suitability should be assessed.

03 Is replacing an old consumer unit always legally required?

No. An older consumer unit is not automatically unlawful simply because a newer design is available. Replacement is normally recommended when the board is unsafe, damaged, unsuitable for the installation, lacks appropriate protection or cannot support planned alterations. A survey or EICR can help establish the condition of the wider installation before a decision is made.

04 What protection can be included in a modern consumer unit?

The final specification depends on the circuits, equipment, property type and electrical design. A modern board may use RCBOs to provide individual overcurrent and residual-current protection, along with surge protection where specified. AFDD protection may also be required or recommended for selected circuits or property types. The devices should be chosen for the installation rather than selected as a one-size-fits-all package.

05 Is a consumer unit replacement notifiable under Part P in England?

In a dwelling in England, replacing a consumer unit is notifiable electrical work under Part P of the Building Regulations. The work can be notified through a registered competent person scheme or handled through the appropriate building control route. The notification process is separate from the Electrical Installation Certificate provided for the completed electrical work.

06 Do the existing circuits need to be tested during the upgrade?

Yes. Replacing the board does not remove faults that may already exist in the wiring. The circuits being reconnected need suitable inspection and testing so the installer can confirm their condition and record the results. A modern RCBO may reveal an earth-leakage or wiring fault that an older fuse box did not disconnect for, so additional remedial work may sometimes be needed.

07 How long does a consumer unit replacement take?

Many straightforward domestic replacements are completed within one working day, but the actual time depends on the number of circuits, access, cable identification, earthing arrangements and whether faults are found during testing. Larger homes, HMOs, commercial sites, multiple boards or difficult locations may need more time. The expected shutdown and working period are discussed before the appointment.

08 Will the electricity be switched off during the work?

Yes. The electrical supply must be safely isolated while the old board is removed and the new consumer unit is installed. Power will remain off for part of the appointment while circuits are reconnected and tested. Save work, shut down sensitive equipment and tell us in advance about alarms, medical devices, refrigeration, servers or other essential systems that need special planning.

09 What happens if testing finds an existing electrical fault?

The affected circuit is identified and the finding is explained before work outside the agreed consumer unit quotation begins. A dangerous or unreliable circuit may need to remain isolated until it is repaired. Additional fault finding, cable repairs or remedial work are priced separately. Once approved work is complete, the circuit is retested and the final result is recorded.

10 Is a consumer unit upgrade the same as rewiring the property?

No. A consumer unit upgrade replaces the distribution board and protective devices, while a rewire replaces some or all of the fixed cables, circuits and accessories. Existing wiring is normally reused during a board change when inspection and testing show that it is suitable for reconnection. Damaged, unsafe or deteriorated circuits may still require separate repair or rewiring.

11 What certificates and records will I receive?

You should receive an Electrical Installation Certificate recording the new work, inspection and test results. The consumer unit should also have clear labels and an updated circuit schedule. Where the work is notifiable in a dwelling, the relevant Building Regulations notification or compliance record is arranged through the chosen notification route. Keep these documents with the property's electrical records.

12 Can the new board allow for future circuits and upgrades?

Yes, where space, supply capacity and the electrical design allow it. Sensible spare capacity can make future work such as extensions, kitchen alterations, EV charging, heat pumps, solar equipment or additional circuits easier to plan. Spare ways do not guarantee that every future load can be connected, because the supply, maximum demand, earthing and cable routes must also be assessed.

13 How much does a consumer unit upgrade cost in London?

Pricing depends on the circuit count, board specification, access, earthing arrangements and the condition of the wiring being reconnected. Benjamin Services' planning ranges are typically £550–£700 for a smaller board, £700–£950 for a standard home and £950–£1,400 or more for larger or more complex properties. Fault repairs, new circuits, supplier equipment and builders' work are quoted separately.

14 What information is needed for a consumer unit upgrade quote?

Send the postcode, property type, a clear photograph of the existing fuse box, the estimated number of circuits and details of any planned electrical work. Mention restricted cupboards, high-level access, multiple consumer units, three-phase supplies or essential equipment that cannot easily lose power. Previous EICRs or electrical certificates can also help us recommend the right survey or quotation route.

Guidance follows information from GOV.UK Approved Document P , Electrical Safety First Best Practice Guide 1 and IET Consumer Unit Guidance .

Need a Consumer Unit Upgrade Quote for Your Property?

Send the postcode, property type, a clear photo of the existing fuse box, the estimated circuit count and details of any planned electrical work.